1. Description
There are 2 bilge areas maintained by 3 bilge pumps:
The switch bank is on a panel by
the nav station.- Lazarette
- Main Bilge
- Upper High-volume Pump
- Float switch – set some 30cm above the bilge-bottom
- Hour counter wired to the Auto wire (assured by a diode).
- This pump should never operate – all water should be handled by the lower pump. This is a high-volume pump designed to both back up the lower pump and handle large volumes in an emergency.
- Lower Low-volume Pump
- Float switch set low in the bilge.
- This pump handles normal small amounts of bilge water.
1.1. Cable Colour Coding
As there are multiple conductors required to operate these pumps, a colour coding scheme has been adopted. The secondary colour in each case is denoted by heat-shrink insulation / coloured cable ties either over the terminal fitting or at regular intervals along the cable. The primary colour is the colour of the cable itself.
Primary Colour |
Secondary Colour |
Designation Code |
---|---|---|
Red | Red | Manual Pump Operation |
Red | Green | Auto Pump Operation (controlled by an automatic switch) |
Red | Blue | Hour Counter ON/OFF |
Black | Black | Negative return |
2. Touch Points
This circuit is powered directly from the house battery busbars. Circuit protection is provided by fuses in the pump switches
3. Power Requirements
This circuit is powered directly from the house battery busbars. Circuit protection is provided by fuses in the pump switches
3. Power Requirements
Section | Component | Circuit Code |
Current |
---|---|---|---|
Lazarette | Pump | P1 | 1.5A |
Main Bilge | Upper High-Volume Pump Lower Low-Volume Pump |
P2 P3 |
20A 2.5A |
Total Overall | 24A |
4. Parts List
Ref. | Description |
---|---|
S1 | Lazarette Bilge-Pump switch unit with 2 settings (Manual / Auto), indicator LEDs and a fuse. |
S2 | Main Upper / High-volume Bilge-Pump switch unit with 2 settings (Manual / Auto), indicator LEDs and a fuse. |
S3 | Main Lower / Low-volume Bilge-Pump switch unit with 2 settings (Manual / Auto), indicator LEDs and a fuse. |
M1 | Hour counter for the Main Upper / High-volume Bilge-Pump. |
FS1 | Main Upper / High-volume float switch |
FS2 | Main Lower / Low-volume float switch |
D1 | Diode to ensure that the hour counter for the Main Upper / High-volume Bilge-Pump only operates in Auto mode |
P1 | Lazarette Bilge-Pump / Float Switch |
P2 | Main Upper / High-volume Bilge-Pump |
P3 | Main Lower / Low-volume Bilge-Pump |