Bilge Pumps - Overview

1. Description
There are 2 bilge areas maintained by 3 bilge pumps:
  • Lazarette
Combined pump / float switch.
  • Main Bilge
Below the galley sink, this is the catch-all for any liquid within the boat. This is serviced by 2 pumps:
  • Upper High-volume Pump
    • Float switch – set some 30cm above the bilge-bottom
    • Hour counter wired to the Auto wire (assured by a diode).
    • This pump should never operate – all water should be handled by the lower pump. This is a high-volume pump designed to both back up the lower pump and handle large volumes in an emergency.
  • Lower Low-volume Pump
    • Float switch set low in the bilge.
    • This pump handles normal small amounts of bilge water.
The switch bank is on a panel by the nav station.
 
1.1. Cable Colour Coding
As there are multiple conductors required to operate these pumps, a colour coding scheme has been adopted. The secondary colour in each case is denoted by heat-shrink insulation / coloured cable ties either over the terminal fitting or at regular intervals along the cable. The primary colour is the colour of the cable itself.

Primary
Colour
Secondary
Colour
Designation
Code
Red Red Manual Pump Operation
Red Green Auto Pump Operation (controlled by an automatic switch)
Red Blue Hour Counter ON/OFF
Black Black Negative return

2. Touch Points
This circuit is powered directly from the house battery busbars. Circuit protection is provided by fuses in the pump switches

3. Power Requirements
Section Component Circuit
Code
Current
Lazarette Pump P1 1.5A
Main Bilge Upper High-Volume Pump
Lower Low-Volume Pump
P2
P3
20A
2.5A
Total Overall 24A

4. Parts List
Ref. Description
S1 Lazarette Bilge-Pump switch unit with 2 settings (Manual / Auto), indicator LEDs and a fuse.
S2 Main Upper / High-volume Bilge-Pump switch unit with 2 settings (Manual / Auto), indicator LEDs and a fuse.
S3 Main Lower / Low-volume Bilge-Pump switch unit with 2 settings (Manual / Auto), indicator LEDs and a fuse.
M1 Hour counter for the Main Upper / High-volume Bilge-Pump.
FS1 Main Upper / High-volume float switch
FS2 Main Lower / Low-volume float switch
D1 Diode to ensure that the hour counter for the Main Upper / High-volume Bilge-Pump only operates in Auto mode
P1 Lazarette Bilge-Pump / Float Switch
P2 Main Upper / High-volume Bilge-Pump
P3 Main Lower / Low-volume Bilge-Pump